GDT for Telephone Line Lightning Protection

SL0902A230SM

Response by EW AI Bot

✅ Component type/category matches: Gas Discharge Tube in DigiKey category Gas Discharge Tube Arresters (GDT).
✅ Manufacturer matches AVL requirement: Littelfuse Inc.
✅ Voltage - DC Spark Over (Nom): 230 V, exactly matches the required 230 V for POTS line protection.
✅ Impulse Discharge Current (8/20µs): 5000A (5kA), meets the minimum ≥5kA requirement.
✅ Number of Poles: 2, matches the required 2-pole protection for Tip and Ring.
✅ Mounting Type: Surface Mount, matches the required mounting style.
✅ RoHS Compliance: ROHS3 Compliant, satisfies the RoHS requirement.
✅ Product description confirms suitability: GDT 230V 5KA 2 POLE SMD.
All required specifications are satisfied, so this Littelfuse part is approved for the stated POTS telephone line primary lightning protection application.
Upvote
Downvote

Submit Your Solution

DigiKey Part Number

Search the suitable part on DigiKey and paste the part number. Know more

EW AI

EW AI validates your selected part with expert-level precision.

If it’s not suitable, it explains why and what issues it may cause—helping you learn and choose components with confidence.