Question.1
The open-drain resolver receives these release-valued controls:
Controller_SDA_Release = 1
Target0_SDA_Release = 0
Target1_SDA_Release = 1
What is the resolved SDA_Bus value?
Serial-interface hardware converts protocol rules into digital circuits.

| Interface | Timing Source | Hardware Action |
|---|---|---|
| UART | Local clock | Rebuild the receive sample timing. |
| SPI | Host-generated SCK | Generate sample and change events. |
| I²C | Shared SCL | Release SCL, then observe SCL_Bus. |
| CAN | Local bit timer | Synchronize to shared-bus edges. |
| Interface | Preferred Term | Meaning |
|---|---|---|
| UART | Baud rate | Symbols per second |
| UART | Bit rate | Bits per second |
| SPI | SCK frequency | Clock cycles per second |
| I²C | SCL frequency | Clock cycles per second |
| CAN | Bit rate or bit time | Bits per second or time per bit |
In binary UART, one symbol normally carries one bit.
Therefore, its baud rate and bit rate have the same numerical value.
| Interface | Bit Order |
|---|---|
| UART | D0 first, D7 last |
| SPI | 8-bit word, MSB first in this architecture |
| I²C | MSB first |
| CAN | Defined by the frame fields |
Important: The TX and RX datapaths must use the same bit order.

| Protocol Need | Digital Hardware |
|---|---|
| Bit timing | Counter and tick generator |
| Frame position | Bit counter and state register |
| TX bit selection | MUX or shift register |
| RX bit capture | Sample enable and receive register |
| Bus ownership | Output-enable or release control |
| Error detection | Comparator and status register |
Circuit scope: Each figure shows one learning-focused circuit block rather than a complete UART, SPI, I²C, or CAN peripheral.
| Name | Idle | Start Bit | Data Bits | Parity Bit | Stop Bit |
|---|---|---|---|---|---|
| Labels / Values | Idle = 1 | 0 | D0 to D7, LSB first | P = Even/Odd, or omitted | 1 |
A TX request is accepted only while the transmitter is idle.
TX_Accept = TX_Start · Busy'
At TX_Accept:
TX_Data.Busy = 1.Later input changes do not affect the active frame.
A new request during Busy = 1 is ignored unless a buffer is provided.
| Block | Function |
|---|---|
| TX data register | Holds the accepted byte |
| Parity logic | Generates P |
| Frame counter | Selects the active frame field |
| Frame MUX | Selects 0, D0...D7, P, or 1 |
| Baud-tick input | External Baud_Tick advances the active frame |
| TX register | Holds one serial bit |
| Control logic | Generates Busy and Done |
Even_Parity = D0 ⊕ D1 ⊕ D2 ⊕ D3 ⊕ D4 ⊕ D5 ⊕ D6 ⊕ D7
Odd_Parity = Even_Parity'
If parity is disabled, the frame MUX skips P.


Direct-I/O simplification:
TX_Start,TX_Data, parity settings, andBaud_Tickare shown as direct inputs. In a complete system, control/configuration registers and the baud generator normally provide them.
For an integer divider:
Baud_Divider = f_CLK_SYS / f_BAUD
The implemented learning circuit uses a 4-bit programmable Baud_Divider. It first generates the terminal limit:
Baud_Limit = Baud_Divider - 1
Implementation note:
1111, the 4-bit two's-complement value of-1, is wired directly to the adder'sBinput whileBaud_DividerdrivesA. The normal adder therefore computesBaud_Divider - 1; no controlled SUB configuration is used.
The value of Baud_Divider must not be 0000
The four counter D flip-flops expose Baud_Count[3:0]. A second 4-bit full adder forms:
Count_Sum = Baud_Count + Enable
Thus Enable = 0 holds the count, while Enable = 1 increments it. A 4-bit magnitude comparator produces:
Terminal_Count = (Baud_Count = Baud_Limit)
Baud_Tick = Enable · Terminal_Count
Each counter-register input masks its corresponding Count_Sum bit with Baud_Tick':
Baud_Count_Next[i] = Count_Sum[i] · Baud_Tick'
Consequently, the counter increments while enabled and below Baud_Limit, generates a one-CLK_SYS-cycle Baud_Tick at the terminal count, and synchronously returns to 0000.
Active-LOW nRESET also clears the four counter flip-flops. The separate UART transmitter circuit receives Baud_Tick as an input, keeping frame sequencing independent of the selected system-clock and baud-rate values.

Direct-I/O simplification:
Baud_DividerandEnableare direct inputs in this circuit. A complete UART normally receives them from configuration and control logic.
The learning circuit is a fixed 8-N-1 receiver. It uses a synchronized RX input and an external 16× Oversample_Tick.
It generates one Sample_Enable near the center of each bit.
Why wait half a bit? The detected falling edge marks the approximate start-bit boundary and may also be caused by a short disturbance. Waiting eight oversample ticks moves the check to the center of the start bit, away from either edge. If RX_SYNC is still LOW there, the start bit is accepted; otherwise it is rejected as a false start.

| Block | Function |
|---|---|
| RX synchronizer | Produces stable local RX |
| Start detector | Finds a possible start edge |
| 4-bit sample counter | Locates the bit center and full-bit boundaries |
| Sample decoder | Pulses Sample_Enable |
| 3-bit bit counter | Selects data bits D0 through D7 |
| RX register | Captures data bits |
| Four-state one-hot controller | Sequences IDLE, START, DATA, and STOP |
| Stop check | Produces RX_VALID or FRAME_ERROR |
1. Synchronize and detect the start edge
Two D flip-flops synchronize RX; a previous-value register then detects the HIGH-to-LOW transition:
Start_Detect = RX_PREV · RX_SYNC'
2. Enable receiver timing
The sample counter runs only while the receiver is validating or receiving a frame:
Timing_Enable = S_START + S_DATA + S_STOP
Count_Enable = Oversample_Tick · Timing_Enable
3. Validate the start-bit center
Count 8 represents half of a 16× bit interval:
Count_8 = C3 · C2' · C1' · C0'
Half_Bit = S_START · Oversample_Tick · Count_8
At Half_Bit, LOW accepts the start bit and HIGH returns the controller to idle as a false start.
4. Sample the eight data bits
After start validation, count 15 produces one full-bit sampling interval:
Count_15 = C3 · C2 · C1 · C0
Bit_Time = Oversample_Tick · Count_15
Sample_Enable = S_DATA · Bit_Time
Bit_Count[2:0] selects D0 through D7. The RX register loads only the selected bit when Sample_Enable = 1.
5. Finish the frame and check the stop bit
Last_Data_Sample = Sample_Enable · B2 · B1 · B0
Stop_Sample = S_STOP · Bit_Time
RX_VALID = Stop_Sample · RX_SYNC
FRAME_ERROR = Stop_Sample · RX_SYNC'
Sample_Count[3:0] and Bit_Count[2:0] are exposed as learning/debug outputs.
Important: The RX register captures only when
Sample_Enable = 1.

Direct-I/O simplification:
Oversample_Tickis supplied directly. A complete UART normally derives this 16× timing pulse from its programmable baud-rate generator.
| Signal | Set When | Included in the learning circuit? |
|---|---|---|
FRAME_ERROR | Sampled stop bit is 0 | Yes |
RX_VALID | Sampled stop bit is 1 and reception completes | Yes |
PARITY_ERROR | Received parity does not match | No; the circuit is 8-N-1 |
OVERRUN | New data arrives before old data is read | No; buffering is omitted |
False starts do not assert RX_VALID.
Scope note: A production receiver must protect unread data and report overrun. The pictured learning circuit intentionally omits that buffer/handshake layer.
TX_Accept.Baud_Tick and select start, data, optional parity, and stop fields.RX and detect its falling start edge.Oversample_Tick, the 4-bit sample counter, and the four-state controller to validate the start bit and generate Sample_Enable.D0 through D7, then sample the stop bit.Busy/Done and RX RX_VALID/FRAME_ERROR.| Property | Value |
|---|---|
| Word size | 8 bits |
| Bit order | MSB first |
| Data flow | Full duplex |
| Clock source | Host-generated SCK |
| Target select | Active-low CS_n |
SPI can also use another bit order when required by the connected device.
CPOL selects the idle level of SCK.
CPOL | SCK Idle | Idle → Active | Active → Idle |
|---|---|---|---|
0 | LOW | Rising edge | Falling edge |
1 | HIGH | Falling edge | Rising edge |
CPHA selects the action performed on each edge.
CPHA | Idle → Active | Active → Idle | First TX Bit |
|---|---|---|---|
0 | Sample | Change | Preload before the first edge |
1 | Change | Sample | Launch on the first edge |
| Mode | CPOL | CPHA | SCK Idle | Idle → Active | Active → Idle |
|---|---|---|---|---|---|
| 0 | 0 | 0 | LOW | Rising: Sample | Falling: Change |
| 1 | 0 | 1 | LOW | Rising: Change | Falling: Sample |
| 2 | 1 | 0 | HIGH | Falling: Sample | Rising: Change |
| 3 | 1 | 1 | HIGH | Falling: Change | Rising: Sample |
| Signal | Meaning |
|---|---|
Clock | System clock for the phase flip-flop |
nRESET | Active-LOW reset that returns Phase to 0 |
Enable | Allows SPI phase changes while a transfer is active |
Half_Tick | One-cycle event marking one half of an SCK period |
CPOL | Selects the idle level of SCK |
CPHA | Selects which phase transition samples data and which changes data |
Phase | Stored half-cycle state; 0 is idle phase and 1 is active phase |
SCK | Generated SPI serial clock, CPOL ⊕ Phase |
Idle_to_Active | Pulse for the first transition away from the idle clock level |
Active_to_Idle | Pulse for the return transition to the idle clock level |
Sample_Edge | Event used to capture the received data bit |
Change_Edge | Event used to update the transmitted data bit |
The learning circuit treats Half_Tick as an external half-period timing pulse. A complete SPI host may generate it with a separate divider, but that divider is not part of this circuit.
The phase T flip-flop toggles only while the controller is enabled:
T_Phase = Enable · Half_Tick
Phase = 0 means the idle half-cycle.
SCK = CPOL ⊕ Phase
The phase transition creates two internal events:
Idle_to_ActiveActive_to_IdleCPHA maps these events to the datapath enables.
Idle_to_Active = Enable · Half_Tick · Phase'
Active_to_Idle = Enable · Half_Tick · Phase
Sample_Edge = CPHA'·Idle_to_Active + CPHA·Active_to_Idle
Change_Edge = CPHA·Idle_to_Active + CPHA'·Active_to_Idle
| Event | Datapath Action |
|---|---|
Sample_Edge | Capture MISO |
Change_Edge | Update MOSI |

Direct-I/O simplification:
Enable,Half_Tick,CPOL, andCPHAare direct inputs, whileSample_EdgeandChange_Edgeare exposed outputs. In a complete SPI host, the transfer controller, timing divider, configuration registers, and datapath connect these signals internally.

| Path | Source | Enable | Action |
|---|---|---|---|
| TX | TX register MSB | Change_Edge | Advance MOSI |
| RX | MISO | Sample_Edge | Capture into RX register |
For CPHA = 0, preload the first MOSI bit before the first sample.
For CPHA = 1, the first Change_Edge launches the first bit.
| Stage | Controller Action |
|---|---|
| Start | Latch the target and assert one CS_n |
| Transfer | Hold the selected target constant |
| Final sample | Finish the required clock phase |
| Complete | Set SCK = CPOL, release CS_n, pulse Done |
Caution: Do not release
CS_nbefore the last clock phase is complete.
| Condition | Target Action |
|---|---|
CS_n = 1 | Ignore SCK |
| Target selected | Preload first MISO bit |
Rising SCK edge | Sample MOSI |
Falling SCK edge | Update MISO |
Enable and the external half-period pulse Half_Tick.T_Phase = Enable · Half_Tick.SCK = CPOL ⊕ Phase so disabled/reset phase returns the clock to its configured idle level.Idle_to_Active and Active_to_Idle from the current phase.Sample_Edge and Change_Edge with CPHA.| Control Value | Participant Action |
|---|---|
0 | Pull the line LOW |
1 | Release the line |
The participant does not actively drive HIGH.
| Participant Outputs | Resolved Bus |
|---|---|
| Every participant releases | HIGH |
| Any participant pulls LOW | LOW |
For release-valued controls:
SDA_Bus = Controller_SDA_Release
· Target0_SDA_Release
· Target1_SDA_Release
SCL_Bus = Controller_SCL_Release
· Target0_SCL_Release
· Target1_SCL_Release
Every device observes SDA_Bus and SCL_Bus.
It does not rely only on its intended output.
The learning circuit implements these equations with two independent native 3-input AND gates: one for SDA and one for SCL. It models one controller and two targets and contains no clock, state machine, or physical pull-up resistor model.

Direct-I/O simplification: The controller and target SDA/SCL release controls are direct inputs here. In a complete I²C design, each participant's protocol controller generates these signals.
Important: Intended output and observed bus value may be different.
| Event | SDA_Bus Action | SCL_Bus Level |
|---|---|---|
| START | HIGH → LOW | HIGH |
| STOP | LOW → HIGH | HIGH |
| Data | Stable | HIGH |
| Repeated START | HIGH → LOW | HIGH, without STOP |
The implemented timing circuit observes the resolved bus with previous-value D flip-flops:
START_Detect = SDA_PREV · SDA_Bus' · SCL_Bus
STOP_Detect = SDA_PREV' · SDA_Bus · SCL_Bus
SCL_Rise = SCL_PREV' · SCL_Bus
START_Detect sets an Active transaction register, and STOP_Detect clears it. While active, a 4-bit full-adder-based counter increments on each SCL_Rise:
D_Active = START_Detect + Active · STOP_Detect'
Count_Enable = Active · SCL_Rise
Count_Clear = START_Detect + ACK_Sample + STOP_Detect
The counter uses Bit_Count + Count_Enable and a synchronous clear mask; protocol events are not connected to the counter's asynchronous clear pins. After eight data clocks:
Byte_Complete = B3 · B2' · B1' · B0'
ACK_Window = Active · Byte_Complete
ACK_Sample = ACK_Window · SCL_Rise
ACK_Detect = ACK_Sample · SDA_Bus'
NACK_Detect = ACK_Sample · SDA_Bus
The ninth rising SCL edge therefore samples ACK or NACK and synchronously restarts the byte counter. The same START detector also recognizes a repeated START while Active = 1.

Direct-I/O simplification:
SDA_BusandSCL_Busare direct inputs to this timing circuit. In the combined system, they come from the open-drain bus resolver or physical input interface.
The controller sends a 7-bit address and R/W.
The address is sent MSB first.
| Bus Phase | SDA Owner | SDA Action |
|---|---|---|
| Address or data bits | Byte transmitter | Pull LOW for 0; release for 1 |
| ACK bit | Byte receiver | Pull LOW for ACK; release for NACK |
The ownership circuit is a single 2:1 MUX using release-valued logic:
SDA_Release = ACK_Window' · TX_Bit
+ ACK_Window · ACK_Release
When ACK_Window = 0, TX_Bit controls SDA. When ACK_Window = 1, the byte receiver's ACK_Release value controls SDA. This circuit does not generate the address, data, or ACK decision; it only performs the ownership handoff.
A target ACKs only a matching address and supported direction.
After a mismatch, it releases SDA until STOP or a new START.

Direct-I/O simplification:
TX_Bit,ACK_Release, andACK_Windoware direct inputs. A complete I²C controller normally generates them from its shift register, ACK decision logic, and timing state.
Caution: The byte transmitter must release SDA during the ACK bit.

A normal transaction starts only when both bus lines are HIGH.
Repeated START is the exception.
When the controller wants SCL HIGH, it sets SCL_Release = 1.
The controller then checks the resolved bus.
Advance_High_Phase = SCL_Release · SCL_Bus
SCL_Release | SCL_Bus | Action |
|---|---|---|
| 1 | 0 | Wait |
| 1 | 1 | Advance or sample |
Check arbitration during controller-owned address and data bits.
Arbitration_Lost_Detect =
Arbitration_Enable · SDA_Intent · SDA_Bus'
| Local Intent | Observed Bus | Result |
|---|---|---|
0 | 0 | Continue |
1 | 1 | Continue |
1 | 0 | Arbitration lost |
On loss:
Arbitration_Lost.ACK_Window, ACK_Sample, ACK_Detect, and NACK_Detect signals.TX_Bit or ACK_Release.SCL_Bus for stretching, and compare intended SDA with the resolved bus for arbitration.Controller Area Network (CAN) is a message-based serial interface for a shared bus.
Frame identifiers select the message and take part in arbitration.

The controller handles the digital protocol.
The transceiver connects it to the physical bus.
| Bit | Name | Meaning |
|---|---|---|
0 | Dominant | Forces the resolved bus LOW |
1 | Recessive | Releases the bus |
A dominant bit wins when nodes transmit different values.
BUS_BIT = Node0_TX · Node1_TX · ...
The controller compares TX_BIT with BUS_BIT during the arbitration field.
ARB_LOST_Detect =
Arbitration_Enable · TX_BIT · BUS_BIT'
The learning circuit implements this expression with one native 3-input AND gate and a bubbled BUS_BIT input. It is a combinational detector only: it does not latch the event, stop the transmitter, or implement retry and fault-state behavior.
TX_BIT | BUS_BIT | Result |
|---|---|---|
| 0 | 0 | Continue |
| 1 | 1 | Continue |
| 1 | 0 | Arbitration lost |
On loss, the node stops transmitting for that attempt.
It continues observing the winning frame.
Important: Arbitration loss is not a frame error.

Direct-I/O simplification:
Arbitration_Enable,TX_BIT, andBUS_BITare direct inputs. In a complete CAN node, they come from the protocol controller and the observed transceiver/bus path;ARB_LOST_Detectthen feeds the controller's arbitration state logic.
| Timing Part | Function |
|---|---|
| Time quantum | Basic timing step |
| Timing segments | Divide one bit time |
| Sample point | Captures BUS_BIT |
| Synchronization | Aligns local timing to bus edges |
| Resynchronization | Applies a limited timing correction |

The transmitter inserts one complementary bit after five equal bits.
The inserted bit does not advance the original frame counter.
The receiver removes a valid stuff bit.
It asserts STUFF_ERROR when the complement is missing.
| Error | Short Meaning |
|---|---|
| Bit error | TX and bus differ unexpectedly |
| Stuff error | Expected complement is missing |
| CRC error | CRC comparison fails |
| Form error | Fixed field has an illegal value |
| ACK error | Required acknowledge is missing |
| Fault State | Meaning |
|---|---|
| Error Active | Normal error signalling allowed |
| Error Passive | Restricted error signalling |
| Bus-Off | Node stops bus participation |
The counter rules and thresholds depend on the controller specification.
Accept = (RX_ID · MASK) == (FILTER_ID · MASK)
Accept = 1 stores the valid received frame.
CAN FD means Controller Area Network with Flexible Data Rate.
| Feature | CAN FD Change |
|---|---|
| Payload | Larger data field |
| Data phase | Optional faster bit rate |
| Bit-rate switching | Selects the faster data phase |
| Frame control | Additional control differences |
TX_BIT with BUS_BIT during arbitration.ARB_LOST_Detect.| Type | Behavior | Examples |
|---|---|---|
| Level | Active while the condition exists | Busy, buffer full |
| Pulse | Active for one CLK_SYS cycle | Done, event pulse |
| Sticky | Held until cleared | Error, Overrun, Timeout |
| Buffer | Use |
|---|---|
| Single register | One word at a time |
| Double buffer | Transfer one word while preparing another |
| FIFO | Store bursts or rate mismatch |
| Risk | Required Protection |
|---|---|
| Active TX word overwritten | Lock it or use a separate buffer |
| Unread RX word overwritten | Preserve it and set Overrun |
| RX buffer full | Set Overflow or apply backpressure |
| Transfer Type | Reused Structure |
|---|---|
| Single asynchronous bit | Synchronizer |
| Controlled multi-bit value | Stable-data handshake |
| Continuous stream | Asynchronous FIFO |
Do not change active protocol settings during a transaction.
| Policy | Action |
|---|---|
| Idle-only write | Reject changes while Busy = 1 |
| Deferred update | Apply after completion |
| Shadow and commit | Copy settings at a safe boundary |
Protected settings include:
CPOL and CPHA
The abort action must not create an illegal bus event.
| Interface | Idle Output |
|---|---|
| UART | TX = 1 |
| SPI | CS_n = 1, SCK = CPOL |
| I²C | SDA and SCL released |
| CAN | Recessive, released, or TX disabled |
| Requirement | Interface |
|---|---|
| Point-to-point link without clock | UART |
| Full-duplex peripheral link | SPI |
| Addressed two-wire bus | I²C |
| Multi-node bus with arbitration | CAN or CAN FD |

The protocol engine controls bit-level operation.
The buffers and status logic connect it safely to the surrounding system.