Question.1
An SPI transfer keeps SCK HIGH while idle. Incoming data is sampled on the first falling edge away from idle, and outgoing data changes on the following rising edge.
Which mode is being used?
Serial-interface hardware converts protocol rules into digital circuits.

| Interface | Timing Source | Hardware Action |
|---|---|---|
| UART | Local clock | Rebuild the receive sample timing. |
| SPI | Host-generated SCK | Generate sample and change events. |
| I²C | Shared SCL | Release SCL, then observe SCL_Bus. |
| CAN | Local bit timer | Synchronize to shared-bus edges. |
| Interface | Preferred Term | Meaning |
|---|---|---|
| UART | Baud rate | Symbols per second |
| UART | Bit rate | Bits per second |
| SPI | SCK frequency | Clock cycles per second |
| I²C | SCL frequency | Clock cycles per second |
| CAN | Bit rate or bit time | Bits per second or time per bit |
In binary UART, one symbol normally carries one bit.
Therefore, its baud rate and bit rate have the same numerical value.
| Interface | Bit Order |
|---|---|
| UART | D0 first, D7 last |
| SPI | 8-bit word, MSB first in this architecture |
| I²C | MSB first |
| CAN | Defined by the frame fields |
Important: The TX and RX datapaths must use the same bit order.

| Protocol Need | Digital Hardware |
|---|---|
| Bit timing | Counter and tick generator |
| Frame position | Bit counter and state register |
| TX bit selection | MUX or shift register |
| RX bit capture | Sample enable and receive register |
| Bus ownership | Output-enable or release control |
| Error detection | Comparator and status register |
Circuit scope: Each figure shows one learning-focused circuit block rather than a complete UART, SPI, I²C, or CAN peripheral.
| Name | Idle | Start Bit | Data Bits | Parity Bit | Stop Bit |
|---|---|---|---|---|---|
| Labels / Values | Idle = 1 | 0 | D0 to D7, LSB first | P = Even/Odd, or omitted | 1 |
A TX request is accepted only while the transmitter is idle.
TX_Accept = TX_Start · Busy'
At TX_Accept:
TX_Data.Busy = 1.Later input changes do not affect the active frame.
A new request during Busy = 1 is ignored unless a buffer is provided.
| Block | Function |
|---|---|
| TX data register | Holds the accepted byte |
| Parity logic | Generates P |
| Frame counter | Selects the active frame field |
| Frame MUX | Selects 0, D0...D7, P, or 1 |
| Baud-tick input | External Baud_Tick advances the active frame |
| TX register | Holds one serial bit |
| Control logic | Generates Busy and Done |
Even_Parity = D0 ⊕ D1 ⊕ D2 ⊕ D3 ⊕ D4 ⊕ D5 ⊕ D6 ⊕ D7
Odd_Parity = Even_Parity'
If parity is disabled, the frame MUX skips P.


Direct-I/O simplification:
TX_Start,TX_Data, parity settings, andBaud_Tickare shown as direct inputs. In a complete system, control/configuration registers and the baud generator normally provide them.
For an integer divider:
Baud_Divider = f_CLK_SYS / f_BAUD
The implemented learning circuit uses a 4-bit programmable Baud_Divider. It first generates the terminal limit:
Baud_Limit = Baud_Divider - 1
Implementation note:
1111, the 4-bit two's-complement value of-1, is wired directly to the adder'sBinput whileBaud_DividerdrivesA. The normal adder therefore computesBaud_Divider - 1; no controlled SUB configuration is used.
The value of Baud_Divider must not be 0000
The four counter D flip-flops expose Baud_Count[3:0]. A second 4-bit full adder forms:
Count_Sum = Baud_Count + Enable
Thus Enable = 0 holds the count, while Enable = 1 increments it. A 4-bit magnitude comparator produces:
Terminal_Count = (Baud_Count = Baud_Limit)
Baud_Tick = Enable · Terminal_Count
Each counter-register input masks its corresponding Count_Sum bit with Baud_Tick':
Baud_Count_Next[i] = Count_Sum[i] · Baud_Tick'
Consequently, the counter increments while enabled and below Baud_Limit, generates a one-CLK_SYS-cycle Baud_Tick at the terminal count, and synchronously returns to 0000.
Active-LOW nRESET also clears the four counter flip-flops. The separate UART transmitter circuit receives Baud_Tick as an input, keeping frame sequencing independent of the selected system-clock and baud-rate values.

Direct-I/O simplification:
Baud_DividerandEnableare direct inputs in this circuit. A complete UART normally receives them from configuration and control logic.
The learning circuit is a fixed 8-N-1 receiver. It uses a synchronized RX input and an external 16× Oversample_Tick.
It generates one Sample_Enable near the center of each bit.
Why wait half a bit? The detected falling edge marks the approximate start-bit boundary and may also be caused by a short disturbance. Waiting eight oversample ticks moves the check to the center of the start bit, away from either edge. If RX_SYNC is still LOW there, the start bit is accepted; otherwise it is rejected as a false start.

| Block | Function |
|---|---|
| RX synchronizer | Produces stable local RX |
| Start detector | Finds a possible start edge |
| 4-bit sample counter | Locates the bit center and full-bit boundaries |
| Sample decoder | Pulses Sample_Enable |
| 3-bit bit counter | Selects data bits D0 through D7 |
| RX register | Captures data bits |
| Four-state one-hot controller | Sequences IDLE, START, DATA, and STOP |
| Stop check | Produces RX_VALID or FRAME_ERROR |
1. Synchronize and detect the start edge
Two D flip-flops synchronize RX; a previous-value register then detects the HIGH-to-LOW transition:
Start_Detect = RX_PREV · RX_SYNC'
2. Enable receiver timing
The sample counter runs only while the receiver is validating or receiving a frame:
Timing_Enable = S_START + S_DATA + S_STOP
Count_Enable = Oversample_Tick · Timing_Enable
3. Validate the start-bit center
Count 8 represents half of a 16× bit interval:
Count_8 = C3 · C2' · C1' · C0'
Half_Bit = S_START · Oversample_Tick · Count_8
At Half_Bit, LOW accepts the start bit and HIGH returns the controller to idle as a false start.
4. Sample the eight data bits
After start validation, count 15 produces one full-bit sampling interval:
Count_15 = C3 · C2 · C1 · C0
Bit_Time = Oversample_Tick · Count_15
Sample_Enable = S_DATA · Bit_Time
Bit_Count[2:0] selects D0 through D7. The RX register loads only the selected bit when Sample_Enable = 1.
5. Finish the frame and check the stop bit
Last_Data_Sample = Sample_Enable · B2 · B1 · B0
Stop_Sample = S_STOP · Bit_Time
RX_VALID = Stop_Sample · RX_SYNC
FRAME_ERROR = Stop_Sample · RX_SYNC'
Sample_Count[3:0] and Bit_Count[2:0] are exposed as learning/debug outputs.
Important: The RX register captures only when
Sample_Enable = 1.

Direct-I/O simplification:
Oversample_Tickis supplied directly. A complete UART normally derives this 16× timing pulse from its programmable baud-rate generator.
| Signal | Set When | Included in the learning circuit? |
|---|---|---|
FRAME_ERROR | Sampled stop bit is 0 | Yes |
RX_VALID | Sampled stop bit is 1 and reception completes | Yes |
PARITY_ERROR | Received parity does not match | No; the circuit is 8-N-1 |
OVERRUN | New data arrives before old data is read | No; buffering is omitted |
False starts do not assert RX_VALID.
Scope note: A production receiver must protect unread data and report overrun. The pictured learning circuit intentionally omits that buffer/handshake layer.
TX_Accept.Baud_Tick and select start, data, optional parity, and stop fields.RX and detect its falling start edge.Oversample_Tick, the 4-bit sample counter, and the four-state controller to validate the start bit and generate Sample_Enable.D0 through D7, then sample the stop bit.Busy/Done and RX RX_VALID/FRAME_ERROR.| Property | Value |
|---|---|
| Word size | 8 bits |
| Bit order | MSB first |
| Data flow | Full duplex |
| Clock source | Host-generated SCK |
| Target select | Active-low CS_n |
SPI can also use another bit order when required by the connected device.
CPOL selects the idle level of SCK.
CPOL | SCK Idle | Idle → Active | Active → Idle |
|---|---|---|---|
0 | LOW | Rising edge | Falling edge |
1 | HIGH | Falling edge | Rising edge |
CPHA selects the action performed on each edge.
CPHA | Idle → Active | Active → Idle | First TX Bit |
|---|---|---|---|
0 | Sample | Change | Preload before the first edge |
1 | Change | Sample | Launch on the first edge |
| Mode | CPOL | CPHA | SCK Idle | Idle → Active | Active → Idle |
|---|---|---|---|---|---|
| 0 | 0 | 0 | LOW | Rising: Sample | Falling: Change |
| 1 | 0 | 1 | LOW | Rising: Change | Falling: Sample |
| 2 | 1 | 0 | HIGH | Falling: Sample | Rising: Change |
| 3 | 1 | 1 | HIGH | Falling: Change | Rising: Sample |
| Signal | Meaning |
|---|---|
Clock | System clock for the phase flip-flop |
nRESET | Active-LOW reset that returns Phase to 0 |
Enable | Allows SPI phase changes while a transfer is active |
Half_Tick | One-cycle event marking one half of an SCK period |
CPOL | Selects the idle level of SCK |
CPHA | Selects which phase transition samples data and which changes data |
Phase | Stored half-cycle state; 0 is idle phase and 1 is active phase |
SCK | Generated SPI serial clock, CPOL ⊕ Phase |
Idle_to_Active | Pulse for the first transition away from the idle clock level |
Active_to_Idle | Pulse for the return transition to the idle clock level |
Sample_Edge | Event used to capture the received data bit |
Change_Edge | Event used to update the transmitted data bit |
The learning circuit treats Half_Tick as an external half-period timing pulse. A complete SPI host may generate it with a separate divider, but that divider is not part of this circuit.
The phase T flip-flop toggles only while the controller is enabled:
T_Phase = Enable · Half_Tick
Phase = 0 means the idle half-cycle.
SCK = CPOL ⊕ Phase
The phase transition creates two internal events:
Idle_to_ActiveActive_to_IdleCPHA maps these events to the datapath enables.
Idle_to_Active = Enable · Half_Tick · Phase'
Active_to_Idle = Enable · Half_Tick · Phase
Sample_Edge = CPHA'·Idle_to_Active + CPHA·Active_to_Idle
Change_Edge = CPHA·Idle_to_Active + CPHA'·Active_to_Idle
| Event | Datapath Action |
|---|---|
Sample_Edge | Capture MISO |
Change_Edge | Update MOSI |

Direct-I/O simplification:
Enable,Half_Tick,CPOL, andCPHAare direct inputs, whileSample_EdgeandChange_Edgeare exposed outputs. In a complete SPI host, the transfer controller, timing divider, configuration registers, and datapath connect these signals internally.

| Path | Source | Enable | Action |
|---|---|---|---|
| TX | TX register MSB | Change_Edge | Advance MOSI |
| RX | MISO | Sample_Edge | Capture into RX register |
For CPHA = 0, preload the first MOSI bit before the first sample.
For CPHA = 1, the first Change_Edge launches the first bit.
| Stage | Controller Action |
|---|---|
| Start | Latch the target and assert one CS_n |
| Transfer | Hold the selected target constant |
| Final sample | Finish the required clock phase |
| Complete | Set SCK = CPOL, release CS_n, pulse Done |
Caution: Do not release
CS_nbefore the last clock phase is complete.
| Condition | Target Action |
|---|---|
CS_n = 1 | Ignore SCK |
| Target selected | Preload first MISO bit |
Rising SCK edge | Sample MOSI |
Falling SCK edge | Update MISO |
Enable and the external half-period pulse Half_Tick.T_Phase = Enable · Half_Tick.SCK = CPOL ⊕ Phase so disabled/reset phase returns the clock to its configured idle level.Idle_to_Active and Active_to_Idle from the current phase.Sample_Edge and Change_Edge with CPHA.| Control Value | Participant Action |
|---|---|
0 | Pull the line LOW |
1 | Release the line |
The participant does not actively drive HIGH.
| Participant Outputs | Resolved Bus |
|---|---|
| Every participant releases | HIGH |
| Any participant pulls LOW | LOW |
For release-valued controls:
SDA_Bus = Controller_SDA_Release
· Target0_SDA_Release
· Target1_SDA_Release
SCL_Bus = Controller_SCL_Release
· Target0_SCL_Release
· Target1_SCL_Release
Every device observes SDA_Bus and SCL_Bus.
It does not rely only on its intended output.
The learning circuit implements these equations with two independent native 3-input AND gates: one for SDA and one for SCL. It models one controller and two targets and contains no clock, state machine, or physical pull-up resistor model.

Direct-I/O simplification: The controller and target SDA/SCL release controls are direct inputs here. In a complete I²C design, each participant's protocol controller generates these signals.
Important: Intended output and observed bus value may be different.
| Event | SDA_Bus Action | SCL_Bus Level |
|---|---|---|
| START | HIGH → LOW | HIGH |
| STOP | LOW → HIGH | HIGH |
| Data | Stable | HIGH |
| Repeated START | HIGH → LOW | HIGH, without STOP |
The implemented timing circuit observes the resolved bus with previous-value D flip-flops:
START_Detect = SDA_PREV · SDA_Bus' · SCL_Bus
STOP_Detect = SDA_PREV' · SDA_Bus · SCL_Bus
SCL_Rise = SCL_PREV' · SCL_Bus
START_Detect sets an Active transaction register, and STOP_Detect clears it. While active, a 4-bit full-adder-based counter increments on each SCL_Rise:
D_Active = START_Detect + Active · STOP_Detect'
Count_Enable = Active · SCL_Rise
Count_Clear = START_Detect + ACK_Sample + STOP_Detect
The counter uses Bit_Count + Count_Enable and a synchronous clear mask; protocol events are not connected to the counter's asynchronous clear pins. After eight data clocks:
Byte_Complete = B3 · B2' · B1' · B0'
ACK_Window = Active · Byte_Complete
ACK_Sample = ACK_Window · SCL_Rise
ACK_Detect = ACK_Sample · SDA_Bus'
NACK_Detect = ACK_Sample · SDA_Bus
The ninth rising SCL edge therefore samples ACK or NACK and synchronously restarts the byte counter. The same START detector also recognizes a repeated START while Active = 1.

Direct-I/O simplification:
SDA_BusandSCL_Busare direct inputs to this timing circuit. In the combined system, they come from the open-drain bus resolver or physical input interface.
The controller sends a 7-bit address and R/W.
The address is sent MSB first.
| Bus Phase | SDA Owner | SDA Action |
|---|---|---|
| Address or data bits | Byte transmitter | Pull LOW for 0; release for 1 |
| ACK bit | Byte receiver | Pull LOW for ACK; release for NACK |
The ownership circuit is a single 2:1 MUX using release-valued logic:
SDA_Release = ACK_Window' · TX_Bit
+ ACK_Window · ACK_Release
When ACK_Window = 0, TX_Bit controls SDA. When ACK_Window = 1, the byte receiver's ACK_Release value controls SDA. This circuit does not generate the address, data, or ACK decision; it only performs the ownership handoff.
A target ACKs only a matching address and supported direction.
After a mismatch, it releases SDA until STOP or a new START.

Direct-I/O simplification:
TX_Bit,ACK_Release, andACK_Windoware direct inputs. A complete I²C controller normally generates them from its shift register, ACK decision logic, and timing state.
Caution: The byte transmitter must release SDA during the ACK bit.

A normal transaction starts only when both bus lines are HIGH.
Repeated START is the exception.
When the controller wants SCL HIGH, it sets SCL_Release = 1.
The controller then checks the resolved bus.
Advance_High_Phase = SCL_Release · SCL_Bus
SCL_Release | SCL_Bus | Action |
|---|---|---|
| 1 | 0 | Wait |
| 1 | 1 | Advance or sample |
Check arbitration during controller-owned address and data bits.
Arbitration_Lost_Detect =
Arbitration_Enable · SDA_Intent · SDA_Bus'
| Local Intent | Observed Bus | Result |
|---|---|---|
0 | 0 | Continue |
1 | 1 | Continue |
1 | 0 | Arbitration lost |
On loss:
Arbitration_Lost.ACK_Window, ACK_Sample, ACK_Detect, and NACK_Detect signals.TX_Bit or ACK_Release.SCL_Bus for stretching, and compare intended SDA with the resolved bus for arbitration.Controller Area Network (CAN) is a message-based serial interface for a shared bus.
Frame identifiers select the message and take part in arbitration.

The controller handles the digital protocol.
The transceiver connects it to the physical bus.
| Bit | Name | Meaning |
|---|---|---|
0 | Dominant | Forces the resolved bus LOW |
1 | Recessive | Releases the bus |
A dominant bit wins when nodes transmit different values.
BUS_BIT = Node0_TX · Node1_TX · ...
The controller compares TX_BIT with BUS_BIT during the arbitration field.
ARB_LOST_Detect =
Arbitration_Enable · TX_BIT · BUS_BIT'
The learning circuit implements this expression with one native 3-input AND gate and a bubbled BUS_BIT input. It is a combinational detector only: it does not latch the event, stop the transmitter, or implement retry and fault-state behavior.
TX_BIT | BUS_BIT | Result |
|---|---|---|
| 0 | 0 | Continue |
| 1 | 1 | Continue |
| 1 | 0 | Arbitration lost |
On loss, the node stops transmitting for that attempt.
It continues observing the winning frame.
Important: Arbitration loss is not a frame error.

Direct-I/O simplification:
Arbitration_Enable,TX_BIT, andBUS_BITare direct inputs. In a complete CAN node, they come from the protocol controller and the observed transceiver/bus path;ARB_LOST_Detectthen feeds the controller's arbitration state logic.
| Timing Part | Function |
|---|---|
| Time quantum | Basic timing step |
| Timing segments | Divide one bit time |
| Sample point | Captures BUS_BIT |
| Synchronization | Aligns local timing to bus edges |
| Resynchronization | Applies a limited timing correction |

The transmitter inserts one complementary bit after five equal bits.
The inserted bit does not advance the original frame counter.
The receiver removes a valid stuff bit.
It asserts STUFF_ERROR when the complement is missing.
| Error | Short Meaning |
|---|---|
| Bit error | TX and bus differ unexpectedly |
| Stuff error | Expected complement is missing |
| CRC error | CRC comparison fails |
| Form error | Fixed field has an illegal value |
| ACK error | Required acknowledge is missing |
| Fault State | Meaning |
|---|---|
| Error Active | Normal error signalling allowed |
| Error Passive | Restricted error signalling |
| Bus-Off | Node stops bus participation |
The counter rules and thresholds depend on the controller specification.
Accept = (RX_ID · MASK) == (FILTER_ID · MASK)
Accept = 1 stores the valid received frame.
CAN FD means Controller Area Network with Flexible Data Rate.
| Feature | CAN FD Change |
|---|---|
| Payload | Larger data field |
| Data phase | Optional faster bit rate |
| Bit-rate switching | Selects the faster data phase |
| Frame control | Additional control differences |
TX_BIT with BUS_BIT during arbitration.ARB_LOST_Detect.| Type | Behavior | Examples |
|---|---|---|
| Level | Active while the condition exists | Busy, buffer full |
| Pulse | Active for one CLK_SYS cycle | Done, event pulse |
| Sticky | Held until cleared | Error, Overrun, Timeout |
| Buffer | Use |
|---|---|
| Single register | One word at a time |
| Double buffer | Transfer one word while preparing another |
| FIFO | Store bursts or rate mismatch |
| Risk | Required Protection |
|---|---|
| Active TX word overwritten | Lock it or use a separate buffer |
| Unread RX word overwritten | Preserve it and set Overrun |
| RX buffer full | Set Overflow or apply backpressure |
| Transfer Type | Reused Structure |
|---|---|
| Single asynchronous bit | Synchronizer |
| Controlled multi-bit value | Stable-data handshake |
| Continuous stream | Asynchronous FIFO |
Do not change active protocol settings during a transaction.
| Policy | Action |
|---|---|
| Idle-only write | Reject changes while Busy = 1 |
| Deferred update | Apply after completion |
| Shadow and commit | Copy settings at a safe boundary |
Protected settings include:
CPOL and CPHA
The abort action must not create an illegal bus event.
| Interface | Idle Output |
|---|---|
| UART | TX = 1 |
| SPI | CS_n = 1, SCK = CPOL |
| I²C | SDA and SCL released |
| CAN | Recessive, released, or TX disabled |
| Requirement | Interface |
|---|---|
| Point-to-point link without clock | UART |
| Full-duplex peripheral link | SPI |
| Addressed two-wire bus | I²C |
| Multi-node bus with arbitration | CAN or CAN FD |

The protocol engine controls bit-level operation.
The buffers and status logic connect it safely to the surrounding system.