54. AC Load Relay Selection

Back To All Submissions
Previous Submission
Next Submission
OJ-SH-112LMH2-ND
Component
DigiKey Part NoOJ-SH-112LMH2-ND
Mfr Part NoOJ-SH-112LMH2
ManufacturerTE Connectivity Potter & Brumfield Relays

RELAY GEN PURP

General Purpose Relay SPST-NO (1 Form A) 12VDC Coil Through Hole

Powered byDigiKey Logo
EW

Response By EW AI

✅ Relay Type: General Purpose matches the requirement.
✅ Mounting Type: Through Hole matches the PCB mounting requirement.
✅ Coil Voltage: 12VDC matches the required 12V coil.
✅ Contact Form: SPST-NO (1 Form A) is acceptable because only normally open switching is needed.
✅ Contact Rating: 8A exceeds the minimum required 5A and is sufficient for a 2A lamp load.
✅ Switching Voltage: 277VAC max is suitable for switching a 230VAC load.
✅ Coil Type: Non Latching matches the requirement.
✅ Termination Style: PC Pin matches the requirement.
✅ Operating Temperature: -40°C to 105°C exceeds the required -40°C to +85°C range.
✅ Approval Agency: cULus is equivalent to the required cURus or equivalent approval.

All required specifications are satisfied. This relay is approved for the stated application.