G5Q-1A DC12
Component
DigiKey Part NoZ219-ND
Mfr Part NoG5Q-1A DC12
ManufacturerOmron Electronics Inc-EMC Div

RELAY GEN PURPOSE SPST 10A 12V

General Purpose Relay SPST-NO (1 Form A) 12VDC Coil Through Hole

Powered byDigiKey Logo
EW

Response By EW AI

✅ Relay Type: General Purpose, matches the requirement.
✅ Mounting Type: Through Hole, matches the PCB relay requirement.
✅ Coil Voltage: 12VDC, exactly matches the required coil voltage.
✅ Contact Form: SPST-NO (1 Form A), acceptable because only normally open switching is needed and SPST-NO is explicitly allowed.
✅ Contact Rating: 10A, exceeds the minimum required ≥5A and is suitable for a 3A motor load.
✅ Switching Voltage: Rated up to 30VDC max, which is suitable for switching a 12VDC motor load.
✅ Coil Type: Non Latching, matches the requirement.
✅ Termination Style: PC Pin, matches the requirement.
✅ Operating Temperature: -40°C to 105°C, exceeds the required -40°C to +85°C range.
✅ Approval Agency: CSA, UR, VDE listed; UR is equivalent to the required cURus or equivalent approval criterion.

All required specifications are satisfied. This relay is approved for the 12V DC motor PCB switching application.