66. Design a Four-Mode SPI Edge and Data-Control Circuit

Loading simulator…

1. Phase and SCK Generation

The phase T flip-flop toggles only on an enabled half-tick event.

T_Phase = Enable·Half_Tick

The serial clock is generated by

SCK = CPOL ⊕ Phase

Resetting Phase to 0 therefore returns SCK to the idle level selected by CPOL.

2. SPI Edge-Decoding Block

The two phase-transition events are:

``text Idle_to_Active = Enable·Half_Tick·Phase' Active_to_Idle = Enable·Half_Tick·Phase


`CPHA` assigns them to their protocol actions through:

```text
Sample_Edge = CPHA'·Idle_to_Active + CPHA·Active_to_Idle
Change_Edge = CPHA·Idle_to_Active + CPHA'·Active_to_Idle

This shared logic supports all four modes:

  • CPOL selects the physical SCK edge direction
  • CPHA selects whether that edge samples or changes data.

3. Transfer-Start and First-Bit Preload Block

An Enable_PREV flip-flop records the previous enable value.

The transfer-start pulse is:

Transfer_Start = Enable·Enable_PREV'

Combining this event with the normal change event gives:

TX_Load = Change_Edge + CPHA'·Transfer_Start

For CPHA = 0, TX_Load preloads the first tx_reg_bit before the first sample edge.

For CPHA = 1, the preload term is disabled and the first bit loads on the first Change_Edge.

4. MOSI Enable-and-Hold Register

The MOSI register loads tx_reg_bit only while TX_Load is HIGH.

Its hold behavior can be expressed as

MOSI_Next = TX_Load·tx_reg_bit + TX_Load'·MOSI

MOSI therefore changes only at the required change event, apart from the intentional CPHA = 0 preload.

5. MISO Sampling Register

The RX register loads the direct MISO input only on Sample_Edge.

Its hold behavior is:

rx_reg_bit_Next = Sample_Edge·MISO + Sample_Edge'·rx_reg_bit 

Between sample events, the previously captured bit remains observable.

6. Reset and Transfer Completion

The digital input nRESET asynchronously clears Phase, Enable_PREV, the MOSI storage, and rx_reg_bit.

The transfer sequence must complete the return edge before clearing Enable, leaving Phase = 0 and SCK = CPOL.