15. Design a Subway Signal Controller

Loading simulator…

Use the one-hot state assignment:

StateQ2Q1Q0
GREEN001
RED010
YELLOW100

The valid-state excitation table is:

Current StateTR_PNXTNext StateD2D1D0PRV
GREEN1XRED0101
GREEN0XGREEN0010
RED1XRED0100
RED01YELLOW1001
RED00RED0100
YELLOW1XRED0101
YELLOW01GREEN0011
YELLOW00YELLOW1000

The D-input equations for valid states are:

D0 = TR_P'·(Q0 + Q2·NXT)
D1 = TR_P + Q1·NXT'
D2 = TR_P'·(Q1·NXT + Q2·NXT')

The Mealy output equation is:

PRV = TR_P·(Q0 + Q2) + TR_P'·NXT·(Q1 + Q2)