Loading simulator…
Here, the sensor drives both a resistor divider and an ADC represented by R_LOAD = 100 kΩ. We must achieve 3 V at ADC_IN for a 10 V input while drawing 500 µA from the sensor, accounting for the ADC load.
R_LOAD = 100 kΩ is already connected across the output, choose R2 such that . This gives , matching the reference solution.Understand the ADC current. At 3 V, the ADC-model resistor draws:
The remaining 470 µA flows through R2. Their sum equals the 500 µA through R1.
Test SENSOR_OUT = 2 V, 4 V, and 10 V. Expect ADC_IN of approximately 0.6 V, 1.2 V, and 3 V, with I_SENSOR of 100 µA, 200 µA, and 500 µA. Experiment by reducing R_LOAD; notice how it alters the scaling.