12. Design ADC interface

Circuit

Loading simulator…

Design Approach

Here, the sensor drives both a resistor divider and an ADC represented by R_LOAD = 100 kΩ. We must achieve 3 V at ADC_IN for a 10 V input while drawing 500 µA from the sensor, accounting for the ADC load.

How the Circuit Works

  1. Set the total input resistance. To draw 500 µA at 10 V, the sensor must see:RTOTAL=10V500μA=20kΩR_{\mathrm{TOTAL}} = \frac{10\,\mathrm{V}}{500\,\mu\mathrm{A}} = 20\,\mathrm{k}\Omega
  2. Set the upper resistance. The upper resistor drops 10−3=7V10 - 3 = 7\,\mathrm{V} at 500 µA, giving:R1=7V0.5mA=14kΩR_{1} = \frac{7\,\mathrm{V}}{0.5\,\mathrm{mA}} = 14\,\mathrm{k}\Omega
  3. Solve for the lower network. The 3 V output requires a lower equivalent of 3V0.5mA=6kΩ\frac{3\,\mathrm{V}}{0.5\,\mathrm{mA}} = 6\,\mathrm{k}\Omega. Since R_LOAD = 100 kΩ is already connected across the output, choose R2 such that R2∥100kΩ=6kΩR_2\parallel100\,\mathrm{k}\Omega=6\,\mathrm{k}\Omega. This gives R2≈6.383kΩR_{2} \approx 6.383\,\mathrm{k}\Omega, matching the reference solution.
  4. Understand the ADC current. At 3 V, the ADC-model resistor draws:3V100kΩ=30μA\frac{3\,\mathrm{V}}{100\,\mathrm{k}\Omega} = 30\,\mu\mathrm{A}

    The remaining 470 µA flows through R2. Their sum equals the 500 µA through R1.

Verify the Circuit

Test SENSOR_OUT = 2 V, 4 V, and 10 V. Expect ADC_IN of approximately 0.6 V, 1.2 V, and 3 V, with I_SENSOR of 100 µA, 200 µA, and 500 µA. Experiment by reducing R_LOAD; notice how it alters the scaling.

Key Learnings

  • Real ADC inputs and external load impedances can affect passive scaling networks.
  • Solving for the parallel equivalent is the reliable way to design a loaded divider.