Loading simulator…
A shunt resistor converts current into a small, measurable voltage. The main trade-off is between signal amplitude and the voltage drop/power lost in the resistor.
Choose the resistance from sensitivity. A 1 A test current must create approximately 100 mV. By Ohm’s law:
This is one of the allowed choices.
R_SHUNT = 0.1 Ω between the test current path and GND. The supplied current source I_TEST and ammeter I_LOAD carry the same current; V_SENSE reads voltage across the shunt.Set I_TEST to 0.5 A, 1 A, and 2 A. Check V_SENSE against 45–55 mV, 90–110 mV, and 180–220 mV, respectively, and verify shunt power stays below 0.5 W.