52. Design current shunt

Circuit

Loading simulator…

Design Approach

A shunt resistor converts current into a small, measurable voltage. The main trade-off is between signal amplitude and the voltage drop/power lost in the resistor.

How the Circuit Works

  1. Choose the resistance from sensitivity. A 1 A test current must create approximately 100 mV. By Ohm’s law:RSHUNT=0.1V1A=0.1ΩR_{\mathrm{SHUNT}}=\frac{0.1\,\mathrm{V}}{1\,\mathrm{A}}=0.1\,\Omega

    This is one of the allowed choices.

  2. Place the shunt in the return path. The solution adds R_SHUNT = 0.1 Ω between the test current path and GND. The supplied current source I_TEST and ammeter I_LOAD carry the same current; V_SENSE reads voltage across the shunt.
  3. Scale the reading. Since VSENSE=ITEST×0.1ΩV_{\mathrm{SENSE}}=I_{\mathrm{TEST}}\times0.1\,\Omega, the expected output is 50 mV at 0.5 A, 100 mV at 1 A, and 200 mV at 2 A.
  4. Check power and burden voltage. At the highest current, shunt power is P=I2R=(2A)2×0.1Ω=0.4WP=I^2R=\left(2\,\mathrm{A}\right)^2\times0.1\,\Omega=0.4\,\mathrm{W}, below the 0.5 W limit. The 200 mV shunt drop is also a real voltage lost from the measured circuit.

Verify the Circuit

Set I_TEST to 0.5 A, 1 A, and 2 A. Check V_SENSE against 45–55 mV, 90–110 mV, and 180–220 mV, respectively, and verify shunt power stays below 0.5 W.

Key Learnings

  • A shunt’s sensitivity is its resistance in volts per ampere.
  • Lower resistance reduces heating and voltage loss but produces a smaller measurement signal.