The same measurement input should produce approximately 200 mV at either 200 mA or 2 A full scale. Two switch-selected shunts give each range the correct sensitivity while ensuring current never flows through both branches simultaneously.
R_LOW = 1 Ω in series with the supplied I_LOW and R_HIGH = 0.1 Ω in series with I_HIGH. The existing SW_RANGE selects exactly one branch from I_TEST; V_SENSE reads the voltage at the selected shunt’s input relative to ground.Set SW_RANGE LOW (OFF), apply 100 mA and 200 mA, and check V_SENSE around 100 mV and 200 mV. Then select HIGH (ON) and apply 2 A; expect 196–204 mV. Confirm the unselected branch meter reads approximately zero.