26. Design hold-up time

Circuit

Loading simulator…

Design Approach

The load must continue receiving voltage briefly after SW1 disconnects the 5 V supply. A capacitor placed across R_LOAD stores energy, but its value must be chosen to satisfy both an early minimum and a later maximum voltage.

How the Circuit Works

  1. Model the discharge. With R_LOAD = 1 kΩ, the hold-up voltage after opening the switch is:VOUT(t)=5e−t/(RLOADC1)VV_{\mathrm{OUT}}(t)=5e^{-t/(R_{\mathrm{LOAD}}C_1)}\,\mathrm{V}
  2. Choose the capacitor. The reference solution adds C1 = 100 µF across R_LOAD. This gives:τ=1kΩ×100μF=100ms\tau = 1\,\mathrm{k}\Omega \times 100\,\mu\mathrm{F} = 100\,\mathrm{ms}
  3. Check 20 ms. The voltage is 5e−20/100V≈4.09V5e^{-20/100}\,\mathrm{V}\approx4.09\,\mathrm{V}, above the required 4 V.
  4. Check 100 ms. The voltage becomes 5e−1V≈1.84V5e^{-1}\,\mathrm{V}\approx1.84\,\mathrm{V}, below the required 2 V. The 100 µF selection therefore meets both bounds; a much larger capacitor might hold the voltage too high at the later check.

Verify the Circuit

With SW1 closed, let VOUT settle near 5 V. Open it and inspect the output 20 ms and 100 ms later. Try 220 µF; it holds voltage longer but would fail the 100 ms upper-voltage requirement.

Key Learnings

  • Capacitor hold-up design involves both minimum and maximum discharge times.
  • Bigger capacitors are not always better when a circuit must also reset promptly.