10. Design loaded divider

Circuit

Loading simulator…

Design Approach

The given RL = 10 kΩ draws current from VOUT, so a standard unloaded-divider calculation would give the wrong answer. The correct approach is to treat the load as part of the lower resistance network.

How the Circuit Works

  1. Find the required lower equivalent. The supplied R1 = 7 kΩ must drop 7 V when VIN = 12 V and VOUT = 5 V. With I_IN = 1 mA, the effective lower resistance must be:5V1mA=5kΩ\frac{5\,\mathrm{V}}{1\,\mathrm{mA}} = 5\,\mathrm{k}\Omega
  2. Account for RL. The fixed RL = 10 kΩ already connects from VOUT to ground. Adding another 10 kΩ in parallel gives 10kΩ∥10kΩ=5kΩ10\,\mathrm{k}\Omega\parallel10\,\mathrm{k}\Omega=5\,\mathrm{k}\Omega.
  3. Complete the design. The solution adds R2 = 10 kΩ from VOUT to GND, in parallel with the existing RL. The total seen by VIN is 7kΩ+5kΩ=12kΩ7\,\mathrm{k}\Omega + 5\,\mathrm{k}\Omega = 12\,\mathrm{k}\Omega.
  4. Understand the current split. At 12 V, 1 mA flows through R1. At the 5 V output node, the current splits equally: 0.5 mA through R2 and 0.5 mA through RL.

Verify the Circuit

At VIN = 12 V, check VOUT≈5VV_{\mathrm{OUT}} \approx 5\,\mathrm{V} and IIN≈1mAI_{\mathrm{IN}} \approx 1\,\mathrm{mA}. Repeat at 6 V and 10 V: expect approximately 2.5 V/0.5 mA and 4.17 V/0.833 mA. Disconnect RL as an experiment; VOUT will increase because the lower equivalent becomes 10 kΩ.

Key Learnings

  • Always include the load impedance in divider calculations.
  • Parallel resistance, not just the named lower resistor, determines a loaded divider’s output.