Loading simulator…
An NPN open-collector output can translate a 3.3 V control into an active-low 5 V signal. However, the provided R_INPUT = 10 kΩ loads the output, so the pull-up must be chosen to reach at least 4.5 V when the transistor is off.
R_PULLUP = 1 kΩ from the 5 V supply to LOGIC_OUT. The existing R_INPUT = 10 kΩ connects the output to ground.Q1 off, the resistors form a divider: , exceeding the 4.5 V requirement.R_B = 4.7 kΩ between CTRL_IN/I_CTRL and the NPN base. At 3.3 V, approximate input current is , below 1 mA.CTRL_IN is HIGH, Q1 conducts and pulls LOGIC_OUT toward ground, typically below 0.4 V in saturation. The output logic is inverted relative to the input control.With CTRL_IN = 0 V, expect . With 3.3 V, expect while I_CTRL < 1 mA. Increase R_PULLUP and observe the loaded HIGH level fall.