Loading simulator…
The pre-defined template already contains the master Clock, the CLK_LOW_EN NOT gate, the SAFE_EN_LATCH D latch, and the CLOCK_GATE AND gate. The latch output is already wired to the Safe_Enable monitor, and the AND output is already wired to Gated_Clock and the State observer. The observer's feedback, VCC, and nReset connections are complete and must be left as supplied.
What is missing is the path that accepts Enable into the latch, the control that makes this latch transparent during the clock's LOW phase, and the two signals entering CLOCK_GATE. Complete these four connections in order:
Enable to the latch data input. Wire DigitalInput-2 (Enable) to the D input (in0) of SAFE_EN_LATCH (LatchD-20). This supplies the requested enable value to the storage element.CLK_LOW_EN (Not Gate-10, pin out) to the latch-enable pin (Pin_clock / IE) of SAFE_EN_LATCH. The NOT gate already receives Clock, so its output is Clock': the latch follows Enable when Clock = 0 and holds it when Clock = 1.Safe_Enable junction (Node-133, connected to the latch Q output) to in0 of CLOCK_GATE (And Gate-30). The gate must use the latch's stored value rather than the raw Enable input, so a HIGH-phase request change cannot alter an ongoing clock pulse.Clock junction (Node-134) to in1 of CLOCK_GATE. With both AND inputs connected, the gate produces Gated_Clock = Clock · Safe_Enable.The completed gate now passes or blocks whole clock HIGH phases according to the value accepted during the preceding LOW phase. The supplied STATE_FF toggles only on the rising edges that reach it through Gated_Clock; no changes to that observer circuit are needed.