Loading simulator…
The input must tolerate normal 24 V operation, 30 V excursions, brief HIGH pulses, and −12 V reversal, while presenting a safe 0–3.3 V signal to the controller. The solution combines one-way input protection, resistive scaling, and RC filtering in a single passive interface.
D1 in series with FIELD_IN, oriented to conduct for positive field voltage and block a −12 V reversal. During negative input, R_BOTTOM pulls the sense node toward ground.Scale the DC voltage. After D1, R_TOP = 82 kΩ feeds SENSE_IN and R_BOTTOM = 10 kΩ connects it to ground. Accounting for approximately 0.635 V diode drop:
At 24 V this is about 2.54 V; at 30 V about 3.19 V—both within the required limits.
C1 = 1 µF connects from SENSE_IN to ground. The effective charging resistance seen by the capacitor is approximately , giving . For a 1 ms 24 V pulse, the output rises only to about , well below 0.8 V.Check FIELD_IN at 24 V settled, 30 V settled, and −12 V settled. Expect SENSE_IN of 2.4–3.2 V, ≤3.3 V, and approximately 0 V. Test a 1 ms HIGH pulse (≤0.8 V) and a sustained 24 V input for 35 ms (≥2.4 V).