47. Light sensor interface

An electronic device measures ambient light intensity using the provided LDR LDR1.

Design a circuit operating from VCC = 3.3 V so that:

  • At 10 lux, ADC_IN ≤ 0.5 V.
  • At 100 lux, ADC_IN remains between 1.3 V and 1.8 V.
  • At 500 lux, ADC_IN ≥ 2.5 V.

Select one resistor from:

1 kΩ, 2.2 kΩ, 4.7 kΩ, 10 kΩ

Example test cases:

Light IntensityRequired ADC_IN
10 lux≤0.5 V
100 lux1.3–1.8 V
500 lux≥2.5 V