Loading simulator…
A discharged 100 µF capacitor initially behaves like a low-impedance load. A series resistor must keep inrush current below 20 mA while still letting the capacitor reach at least 10.5 V within 150 ms.
SW1 closes, . For VIN = 12 V:R1 = 680 Ω between the existing I_IN ammeter and C1 = 100 µF.Check the charging deadline. The time constant is:
At 150 ms, , exceeding the 10.5 V minimum.
Start with C1 discharged and SW1 open. Close the switch, examine the initial I_IN, then measure VC at 150 ms. Compare with R1 = 1 kΩ: inrush falls, but the capacitor charges too slowly for the deadline.