Loading simulator…
An ADC that accepts only 0–3.3 V cannot directly read a −3 V to +3 V sensor. The solution combines attenuation and a positive reference offset so zero sensor voltage maps to midscale.
R_SIGNAL = 47 kΩ from SIGNAL_IN to ADC_IN, and R_REF = 47 kΩ from the supplied VREF = 3.3 V through I_REF to ADC_IN. With a high-impedance output probe, the junction is the average of the two applied voltages.R_REF is , inside the required 50–100 µA range.Set SIGNAL_IN to −3 V, 0 V, and +3 V. Expect , 1.65 V, and 3.15 V. At −3 V, verify I_REF is between 50 µA and 100 µA. Try unequal resistor values and observe how the gain and offset change together.