The pre-defined circuit contains faults in both product-term programming and macrocell control settings. The faulty AND-plane programming produces:
PT0 = A.Q
PT1 = A'.B'.Q'
Din = A.Q + A'.B'.Q'The solution removes Q from PT0, so PT0 becomes A. For PT1, it removes A', replaces complemented feedback Q' with true feedback Q, and keeps B' selected. It also changes PT1_EN from 0 to 1 so the corrected second product term contributes to Din.
PT0 = A
PT1 = B'.Q
Din = A + B'.QThe control settings are also corrected. mode_sel changes from 0 to 1 to select the registered output. polarity changes from 1 to 0 so the result is not inverted. CE changes from 0 to 1 so the register can capture the corrected Din value on a rising edge.
After these changes, RST = 1 clears the register synchronously, CE = 1 captures Din, and CE = 0 holds the previous value.