Loading simulator…
A signal normally between 0 V and 3.3 V can damage a controller when a fault drives it to −12 V. A series resistor limits fault current, while a diode to ground clamps the protected node near one diode drop below 0 V.
R1 = 6.2 kΩ between SIGNAL_IN and PROTECTED_IN, leaving the existing R_LOAD = 100 kΩ connected to ground.D1 connects from ground (through the supplied I_D measurement path) to PROTECTED_IN, with its anode toward ground and cathode at the signal node. Positive inputs reverse-bias the diode.D1 is off. The 100 kΩ load and 6.2 kΩ resistor form a weak divider, giving , within the 3.1–3.3 V requirement.D1 conducts and clamps the node around −0.6 to −0.7 V. Approximate fault current is , below the 2 mA limit.Check SIGNAL_IN at +3.3 V, 0 V, and −12 V. Verify normally and no lower than −0.9 V during the fault, with .