30. Protect negative input

Circuit

Loading simulator…

Design Approach

A signal normally between 0 V and 3.3 V can damage a controller when a fault drives it to −12 V. A series resistor limits fault current, while a diode to ground clamps the protected node near one diode drop below 0 V.

How the Circuit Works

  1. Insert a current limiter. The solution adds R1 = 6.2 kΩ between SIGNAL_IN and PROTECTED_IN, leaving the existing R_LOAD = 100 kΩ connected to ground.
  2. Add a negative clamp. D1 connects from ground (through the supplied I_D measurement path) to PROTECTED_IN, with its anode toward ground and cathode at the signal node. Positive inputs reverse-bias the diode.
  3. Preserve normal signaling. At +3.3 V, D1 is off. The 100 kΩ load and 6.2 kΩ resistor form a weak divider, giving PROTECTED_IN≈3.3×100106.2≈3.11V\mathrm{PROTECTED\_IN} \approx \frac{3.3 \times 100}{106.2} \approx 3.11\,\mathrm{V}, within the 3.1–3.3 V requirement.
  4. Limit fault current. At −12 V, D1 conducts and clamps the node around −0.6 to −0.7 V. Approximate fault current is 12−0.6356.2kΩ≈1.83mA\frac{12 - 0.635}{6.2\,\mathrm{k}\Omega} \approx 1.83\,\mathrm{mA}, below the 2 mA limit.

Verify the Circuit

Check SIGNAL_IN at +3.3 V, 0 V, and −12 V. Verify PROTECTED_IN≥3.1V\mathrm{PROTECTED\_IN} \ge 3.1\,\mathrm{V} normally and no lower than −0.9 V during the fault, with |ID|≤2mA\lvert I_D\rvert\le2\,\mathrm{mA}.

Key Learnings

  • The series resistor and diode work together: one limits current; the other limits voltage.
  • Clamp protection must be designed for both normal-signal accuracy and worst-case fault current.