33. Radix-4 Booth Partial-Product Generator

Loading simulator…

Complete the predefined template in the following order.

1. Connect the widened multiplicand paths

Create the 6-bit signed forms:

Mext  = {M3, M3, M3, M2, M1, M0}
2Mext = {M3, M3, M2, M1, M0, 0}

Connect Mext to the first MUX bank and 2Mext to the second MUX bank.

2. Complete the Booth-control logic

Generate:

SEL_M  = Q0 ⊕ Q-1
SEL_2M = (Q1 ⊕ Q0) · SEL_M'
NEG    = Q1 · (Q0 · Q-1)'

Connect:

  • SEL_M to all first-stage MUX select inputs.
  • SEL_2M to all second-stage MUX select inputs.
  • NEG to all six XOR gates.

The two MUX stages then select:

000,111           → 0
001,010,101,110 → Mext
011,100           → 2Mext

3. Complete conditional negation

Connect NEG to the Cin of the least-significant Full Adder PP_FA0.

The XOR and Full Adder stages implement:

X  = Selected ⊕ {6{NEG}}
PP = X + NEG

Therefore:

NEG = 0 → PP = Selected
NEG = 1 → PP = Selected' + 1

So the circuit produces the required 0, +M, -M, +2M, or -2M.

For example, if:

M = 0101
Q1 Q0 Q-1 = 100

then:

Selected = 2M = 001010
NEG = 1

PP = 110101 + 1
PP = 110110 = -10

Thus Booth code 100 correctly generates -2M.