34. Regulate changing load

Circuit

Loading simulator…

Design Approach

A Zener shunt regulator must tolerate changing load current, including a disconnected load. The resistor needs to leave enough Zener current under heavy loading without exceeding the diode’s power rating when the load disappears.

How the Circuit Works

  1. Check the heaviest load. With R_LOAD = 330 Ω, a 5.1 V output needs:ILOAD=5.1330≈15.45mAI_{\mathrm{LOAD}} = \frac{5.1}{330} \approx 15.45\,\mathrm{mA}

    The Zener also requires at least 2 mA, so the series current must be at least 17.45 mA.

  2. Choose the allowed resistor. From the task choices, the solution uses R1 = 390 Ω. At VIN = 12 V, it supplies 12−5.1390≈17.69mA\frac{12 - 5.1}{390} \approx 17.69\,\mathrm{mA}.
  3. Check regulation under load. With a 330 Ω load, the remaining Zener current is approximately 17.69−15.45=2.24mA17.69 - 15.45 = 2.24\,\mathrm{mA}, enough for the specified minimum.
  4. Check the unloaded power. With LOAD_ENABLE open, essentially all 17.69 mA flows through DZ1. Its approximate power becomes 5.1V×17.69mA≈90.2mW5.1\,\mathrm{V} \times 17.69\,\mathrm{mA} \approx 90.2\,\mathrm{mW}, below the 100 mW ceiling. The supplied adjustable R_LOAD and LOAD_ENABLE remain in the load branch.

Verify the Circuit

At VIN = 12 V, test LOAD_ENABLE ON with R_LOAD = 330 Ω and 1 kΩ, then OFF. Expect approximately 5.1 V in each case, IZ≥2mAI_{\mathrm{Z}} \ge 2\,\mathrm{mA} at 330 Ω, and Zener power below 100 mW when disconnected.

Key Learnings

  • The worst case for Zener current often occurs with the load disconnected.
  • A series resistor must be checked at both maximum load and minimum load, not merely at nominal operation.