29. Shared Add/Sub Unit with Status Flags

Loading simulator…

The predefined circuit already contains the 4-bit FullAdder, B-conditioning XOR gates, and status-logic gates. Complete the missing connections as follows.

1. Complete the shared Add/Sub control

Connect the same SUB signal to all four B-conditioning XOR gates and to the FullAdder carry input Ci.

BX0 = B0 XOR SUB
BX1 = B1 XOR SUB
BX2 = B2 XOR SUB
BX3 = B3 XOR SUB

Ci = SUB

This makes the same datapath perform both operations:

SUB = 0 → BX = B,     Ci = 0 → S = A + B
SUB = 1 → BX = NOT B, Ci = 1 → S = A + NOT(B) + 1 = A - B

2. Complete the Carry/Borrow output

Connect the FullAdder carry-out Co and SUB to the CB XOR gate.

CB = Co XOR SUB

Therefore:

SUB = 0 → CB = Co       → carry-out
SUB = 1 → CB = NOT(Co)  → unsigned borrow

3. Complete the Overflow logic

Use the sign bits A3, BX3, and S3.

Overflow = NOT(A3 XOR BX3) AND (A3 XOR S3)

A3 XOR BX3 checks whether the two effective operands have different signs.
After inversion, it becomes 1 when their signs are the same.
A3 XOR S3 becomes 1 when the result sign differs from A.

Overflow is asserted only when both conditions are true.

4. Complete the Negative output

Connect the result MSB directly to Negative.

Negative = S3

A 4-bit two's-complement result is negative whenever its MSB is 1.

5. Complete the Zero output

Connect all four result bits to the supplied OR network and invert the final OR result.

Zero = NOT(S0 OR S1 OR S2 OR S3)

Thus Zero = 1 only when:

S[3:0] = 0000

The completed circuit now performs 4-bit addition/subtraction and produces CB, Overflow, Zero, and Negative from the same shared arithmetic datapath.