51. Temperature-controlled cooling

Circuit

Loading simulator…

Design Approach

The fan must switch on when the device becomes hot without using a microcontroller. The reference uses an NTC thermistor to sense temperature, an NPN transistor to convert sensor voltage into a gate-control signal, and a P-channel MOSFET to power the 12 V motor.

How the Circuit Works

  1. Create the sensor bias. The supplied V_SENSOR = 5 V reaches NTC1 through the provided I_SENSOR meter. The solution adds R_BIAS = 500 Ω from the thermistor output/base node to ground. That node also drives the base of NPN Q1.
  2. Turn the fan off when cool. At 25°C, the 10 kΩ NTC is relatively resistive. With R_BIAS = 500 Ω, its base-control voltage is approximately 5×50010000+500≈0.24V\frac{5 \times 500}{10000 + 500} \approx 0.24\,\mathrm{V}, too low to turn on Q1. The added R_PULL = 10 kΩ then holds the P-channel Q2 gate near its 12 V source, keeping MOTOR off.
  3. Turn the fan on when hot. As the NTC warms, its resistance falls. At 60°C and 75°C, the base node rises enough to drive Q1. The NPN pulls Q2's gate toward ground, making its gate-source voltage negative. Q2 conducts from VCC = 12 V to MOTOR, which returns to ground.
  4. Separate sensing and load power. The 5 V thermistor network controls a transistor but does not power the fan. The motor draws from the 12 V rail through Q2. The design must keep |I_SENSOR| < 3 mA while ensuring motor current reaches at least 90 mA at the two hot test points.

Verify the Circuit

Test NTC1 at 25°C, 60°C, and 75°C. Expect MOTOR current magnitude ≤1 mA at 25°C, and ≥90 mA at 60°C and 75°C, while |I_SENSOR| remains below 3 mA. Vary R_BIAS experimentally to see how it shifts the switching temperature.

Key Learnings

  • An NTC divider plus transistor can implement automatic temperature-dependent switching without digital control.
  • A sensor-stage transistor can safely control a higher-voltage MOSFET while keeping sensor and motor power paths separate.