Loading simulator…
A standard flyback diode limits the coil’s reverse voltage to about one diode drop, producing a relatively slow current decay. A diode and Zener combination allows a larger controlled reverse coil voltage, releasing the relay faster while keeping Q1 below its voltage limit.
Q1 as a low-side switch, RG = 330 Ω for its gate drive, and RPD = 100 kΩ as a gate pull-down. The 12 V coil and lamp switching path remain separate.D1 and DZ1 are placed in series across the coil. The reference chooses DZ1 = 12 V. During normal energization, the network blocks current; after turn-off it conducts when the reverse voltage reaches the diode plus Zener breakdown voltage.Q1’s drain can rise to roughly , remaining below the 27 V limit.K1’s OpTime from 2 ms to 1 ms and RelTime from 500 µs to 100 µs; those are separate relay-model changes, not consequences of the clamp alone.Drive CTRL_IN HIGH until the relay is energized, then switch it LOW. Check coil current ≤10 mA after 0.7 ms and maximum Q1 drain-source voltage ≤27 V. The lamp should subsequently turn OFF. Experiment with a lower Zener value to see slower decay and reduced drain stress.
The reference solution changes K1's OpTime and RelTime properties compared with the template. These edits should be distinguished from the electrical improvement due to DZ1; otherwise the task suggests a flyback-only change when relay dynamics were also altered.