Prev Problem
Next Problem

46. GDT for 230VAC Mains Primary Surge Protection

Back To All Submissions
Previous Submission
Next Submission
CG2470L
Component
DigiKey Part NoF2739-ND
Mfr Part NoCG2470L
ManufacturerLittelfuse Inc.

GDT 470V 20KA 2 POLE TH

Gas Discharge Tube 470 V 20000A (20kA) 2 Pole Through Hole

Powered byDigiKey Logo
EW

Response By EW AI

✅ Component type/category is correct: Gas Discharge Tube in DigiKey category Gas Discharge Tube Arresters (GDT).
✅ Manufacturer matches AVL requirement: Littelfuse Inc.
✅ Voltage - DC Spark Over (Nom): 470 V, exactly matches the required 470 V for 230 VAC mains primary protection.
✅ Impulse Discharge Current (8/20µs): 20000A (20kA), which exceeds the minimum required 10kA.
✅ Number of Poles: 2, matches the required line-neutral 2-pole protection.
✅ Mounting Type: Through Hole, matches the required power-stage mounting style.
✅ RoHS Compliance: ROHS3 Compliant, satisfies the RoHS requirement.
✅ Package/details are consistent with a through-hole 2-pole GDT suitable for first-stage primary surge protection in a multi-stage SPD.
All required specifications are satisfied, so this Littelfuse part is approved.
Was this helpful?
Upvote
Downvote