A multimeter’s current measurement path passes the measured current directly through the meter. If the user accidentally connects the meter across a voltage source while in current mode, a very large current flows through the meter.
The current measurement fuse protects the meter’s internal shunt resistor and circuitry from this fault current. A fast-blow fuse disconnects the path as quickly as possible to prevent internal damage.
Important: This is a direct replacement fuse. Current rating, response time, and physical size must match exactly. Do not substitute with a different current or a slow-blow type.
3. Key Specifications & What They Mean
Specification
Required
Why
Fuse Type
Cartridge, Glass
Standard instrument-grade fuse body.
Current Rating
0.5A (500mA)
Must match instrument manual exactly.
Voltage Rating
≥250VAC
Meter may be used on mains circuits.
Response Time
Fast Blow
Quick disconnect to protect meter internals.
Size
5mm × 20mm
Must fit existing fuse holder in the meter.
Manufacturer
Littelfuse
Company AVL requirement.
RoHS
Yes
Compliance required.
4. Selecting a Safe, Production-Ready Part
The filtered list will show matching parts. Before you pick one, check: Is it Active? Is stock available? Is a datasheet available?