Linda is designing the input stage of a 230VAC single-phase industrial power supply.
To protect the circuit from mains voltage surges and transients, she needs to place a Metal Oxide Varistor (MOV) across the line and neutral after the input fuse.
The MOV must safely handle 230VAC continuous without degrading, and should clamp surge voltages to protect downstream components.
She wants a through-hole disc type MOV for easy PCB assembly.
The company's approved vendor list (AVL) specifies Littelfuse for circuit protection components, so the part must be selected from Littelfuse on DigiKey.

Help her select a suitable MOV from Littelfuse on DigiKey.
Visit DigiKey's MOVs category and find a suitable part.
A Metal Oxide Varistor (MOV) is a surge-protection component
Think of it as a “voltage safety valve” in your circuit.

Schematic Symbols:

Simple MOV circuit diagram:

V-I Characteristics of a TVS Diode:

MOV used in Power Line

| Type | Image | Description |
|---|---|---|
| Radial Leaded | ![]() | Used for general surge protection in power supplies and electronic circuits. |
| Surface Mount (SMD) | ![]() | Used for compact surge protection in consumer electronics and dense circuits. |
| Thermally protected (TMOV) | ![]() | Used in UPS, inverters, and power strips for safe protection with thermal cutoff. |
| Industrial High-Energy Block | ![]() | Used in power lines and outdoor/industrial equipment for handling high surges. |
| Axial Leaded | ![]() | Used for low-energy surge protection in signal lines and small circuits |
Example Littelfuse TMOV Series MOV Specifications:

| Specification | Value for TMOV14RP150E |
|---|---|
| Maximum Continuous Operating Voltage (MCOV) | 150 VAC 200 VDC |
| Varistor Voltage (V1mA) | 240 V (Nominal) 216 V (Min) – 264 V (Max) |
| Clamping Voltage (Vc) | 395 V |
| Maximum Surge Current (Imax) | 6,000 A (1 pulse) 4,500 A (2 pulses) |
| Energy Rating (Wtm) | 60 Joules |
| Capacitance | 800 pF (Typical) |
| Operating Temperature | -55°C to +85°C |
| Leakage Current | Microamp range |
| Thermal Protection | Integrated Thermal Element |
When designing with a Metal Oxide Varistor (MOV), you must evaluate specific electrical parameters to ensure the device protects the circuit without failing prematurely.
Feature | TVS Diode | MOV (Metal Oxide Varistor) | GDT (Gas Discharge Tube) |
|---|---|---|---|
Image | ![]() | ![]() | ![]() |
Response Speed | Ultra-fast (<1 ns) → ESD & fast spikes | Fast (100 ns – µs) → mains surges | Slow (µs–ms) → lightning surges |
Clamping Precision | Very precise (protects 3.3 V, 5 V, 12 V ICs) | Moderate (hundreds of volts range) | Poor (fires at 75–600 V, not exact) |
Energy Handling | Low (Watts level) | Medium–High (tens–thousands of Joules) | Very High (kiloamp lightning strikes) |
Best Application | IC-level, USB, HDMI, RS-485, automotive pins | AC mains, SMPS, automotive load dump | Telecom lines, outdoor gear, power grids |
Lifetime | Good for repeated ESD | Degrades after multiple surges (aging) | Very durable for big surges, but slow |